White Paper From Tate(R) Identifies Server Leakage as Large Potential Source of Bypass Air in Contained Cold Aisles

JESSUP, MD — (Marketwire) — 04/05/12 — , a market leader in the manufacture of raised floors and airflow management solutions, has issued a that identifies server leakage as a large potential source of bypass air in contained cold aisles. Tate conducted a study of 10 servers from five leading manufacturers and found the servers will leak cold air into the hot aisle at a rate of 23 to 135 percent of their designed flow rate, when a positive static pressure is experienced at the server inlet. Leakage at these rates will significantly impact annual energy costs to operate data centers.

In response to these findings, Tate is expanding its product offering for the market with , a pressure sensing, automatic variable-air-volume damper that minimizes bypass airflow through servers, racks and other containment structures.

Constant airflow into a contained system with a variable-load profile wastes energy during times of nonpeak load performance as airflow is forced through servers and other spaces in the containment structure. The Tate study indicates as much as 300 to 600 cfm of bypass airflow can be forced through a 42U rack of servers in idle mode. By installing SmartAire P under a portion of the airflow panels in the cold aisle, airflow can be automatically varied to maintain a desired static pressure.

When servers enter an idle state, they draw less air from the contained system, causing static pressure in the aisle to increase. As the static pressure increases, more air is forced through the servers, even when fan speeds are reduced. The SmartAire P is daisy chained to units for a primary/secondary configuration that automatically modulates all dampers in the aisle to control the static pressure and maintain a user defined set point. The resulting balance eliminates leakage through idle servers and other gaps in the containment structure.

To learn more about Tate-s data center solutions, download . The server leakage white paper is also available for download at .

For information about other Tate products and services, please visit or call (410) 799-4200.

Tate is a leading manufacturer of raised access floors and in-floor cooling systems for data centers. Tate offers innovative solutions to effectively manage the diverse, variable, and high density heat loads commonly found in data centers. In-floor cooling systems such as SmartAire, DirectAire and PowerAire help reduce PUE and create an energy efficient data center. As the market leader, Tate supplies best-in-class raised access floors that provide flexibility to meet the any service distribution requirement.

Tate

white paper

data center

SmartAire P

SmartAire C

Containment Solutions brochure

Image Available:

Jonathan Bishop
Godfrey(717) 393-3831

Scott Alwine
Tate
(410) 799-4790

You must be logged in to post a comment Login


Blogverzeichnis - Blog Verzeichnis bloggerei.de Blog Top Liste - by TopBlogs.de Bloggeramt.de blogoscoop